Spin Columns are designed to hold
up to 900µL volume of resin or buffer. Whether it is a mini spin or a micro spin column, it is can be placed
in microcentrifuge tubes of capacity 1.5mL or 2.0mL. These columns can also be used
with a Luer-Lok Adapter with a syringe for processing samples. While a syringe
is used, sample size, as well as wash volumes, is only restricted by the volume
capacity of the syringe. These columns are used with only the small, pre-introduced
frit in the case of small volumes of resin.
For applications that involve the
requirements of over 100µL of resins, the big frit may be used at either the bottom
or top of the resin bed. Resins may be prepared for frequent use when the resin
is inserted between the large and small frit.
You would get many benefits when
you use a micro spin column. One of
the notable benefits of using these columns is that they are the most convenient
tools for maneuvering small volumes of affinity supports, usually between 5 and
100 µL, for protein purification.
Some of the beneficial features
of these columns include:
·
They are the ideal tools to be used for
extremely small resin and sample numbers.
·
They are extremely convenient to use with the column
volume of 400 µL and resin volume between 5 and 100 µL.
·
They are available with the highest quality Polyethylene
filter with the approximate pore size of 30 µm
· They come with both press-on bottom caps a well
as with O-ring screw top caps.
Another major benefit of using a micro spin column is that it is easy to
use. Users are just required to add the sample and affinity resin to one of these
micro-spin columns. They can then wash away the contaminants efficiently by
making use of a microcentrifuge. They will be capable of eluting their
disinfected sample without the loss of resin during the process.
Above all, a micro spin column allows users to disinfect more protein in less
time, which makes it suitable to use in a variety of applications.
Whether you are using a micro spin
or a mini spin column, you need to
follow some procedures to adjust frits in these spin columns. These procedures
include:
1. To eliminate a frit, which is
placed in the column, you are required to use a spread-out paper clip and
introduce the wire through the tip of the column and push the frit.
2. If you want to insert a frit,
you need to place the frit inside the micro or mini spin column and push the frit into position by making use of
the frit tool.
3. You are required to use an
extended paper clip to tip the top frit up if you want to take the top frit
away from an already-filled column with a bottom and top frit. You can then remove the top frit with
tweezers.
You are also supposed to follow some
general procedures for using a micro spin or a mini spin column during the process of affinity purification.